ELTDIS2=0, ELTDIS5=0, ELTDIS3=0, ELTDIS4=0, ELTDIS1=0, ELTDIS0=0
ELC Output Timer Select Register
ELTDIS0 | Pulse Output Timer 0 Event Generation Disable 0 (0): Pulse output timer 0 is used for the generation of event signals for the ELC. 1 (1): Pulse output timer 0 is not used for the generation of event signals for the ELC. |
ELTDIS1 | Pulse Output Timer 1 Event Generation Disable 0 (0): Pulse output timer 1 is used for the generation of event signals for the ELC. 1 (1): Pulse output timer 1 is not used for the generation of event signals for the ELC. |
ELTDIS2 | Pulse Output Timer 2 Event Generation Disable 0 (0): Pulse output timer 2 is used for the generation of event signals for the ELC. 1 (1): Pulse output timer 2 is not used for the generation of event signals for the ELC. |
ELTDIS3 | Pulse Output Timer 3 Event Generation Disable 0 (0): Pulse output timer 3 is used for the generation of event signals for the ELC. 1 (1): Pulse output timer 3 is not used for the generation of event signals for the ELC. |
ELTDIS4 | Pulse Output Timer 4 Event Generation Disable 0 (0): Pulse output timer 4 is used for the generation of event signals for the ELC. 1 (1): Pulse output timer 4 is not used for the generation of event signals for the ELC. |
ELTDIS5 | Pulse Output Timer 5 Event Generation Disable 0 (0): Pulse output timer 5 is used for the generation of event signals for the ELC. 1 (1): Pulse output timer 5 is not used for the generation of event signals for the ELC. |